Where do I configure Quality Control?#
Use the Control setup area under Settings/Tools with an authorized account. Configure the intended laboratory test, controls, lot/levels and applicable settings before recording routine runs. Confirm units and availability. Changes should follow the laboratory’s approved QC procedure; the software cannot decide which control material is suitable for a method.
How do I enter a control result?#
Open Control, choose the intended configured test/control context and enter the observed values with their units. Check the lot, level and run information, then save through the normal workflow. Read the resulting evaluation and any hold/review information. A numeric entry is not itself approval to release patient work.
Why is a QC control unavailable?#
The test/control/lot may be inactive, missing a required level or configuration, outside the intended context, or restricted by permissions. Review the actual error and setup. Do not select a similarly named control for a different parameter merely to bypass the refusal.
How do QC holds affect patient results?#
QC rules can hold or require review of affected work. Resolve the control problem under the laboratory procedure and use the supported authorized release/review action. A later passing rerun does not automatically erase a prior hold or substitute for the required review.
Does a passing control automatically verify patient results?#
No. QC evaluation and patient result verification are separate workflows. Check the patient result and its clinical context, resolve any hold/review requirement and verify only with an authorized account. Never treat a green QC status as a signature on every pending visit.
How do I review QC history?#
Use the available control history/view for the selected test and context. Compare run dates, lots, levels and values with the saved evaluation. Do not compare numbers across different units or materials without justification. Retain the original evidence when investigating an outlier or repeated run.
How does the factor calculator work?#
The simple factor calculation is current factor × target value ÷ measured value. Enter values appropriate to the method and check that the measured value is valid and nonzero. Review the result before applying it elsewhere. Calculating a number does not itself change the stored quality-control configuration.
Can I use a comma as a decimal separator?#
Follow the field’s supported numeric format and the displayed validation. Do not assume a comma is always a decimal separator or always a thousands separator. Check the saved value after entry. When reporting a parsing problem, include the field, language and an example without patient information.
How do I handle multiple QC levels?#
Enter the configured required levels for the intended run and review completeness before saving. A partial run may require an explicit reason or remain unsuitable for normal assessment. Do not enter the same measurement into another level to make the run appear complete.
What if QC recording fails halfway through?#
Read the outcome and refresh the relevant history before retrying. The normal save workflow aims to keep a run and its related decisions consistent. Do not assume a failed message means nothing was stored or repeatedly click Save without checking. Preserve the error for support if the UI and history disagree.
Should I delete a failed control to remove a warning?#
A failed control is evidence that needs investigation, not cosmetic cleanup. Use the supported review, correction or discard procedure appropriate to the run and permissions. Do not remove database rows or alter historical values to make an evaluation pass.
Can I use patient samples to test quality control?#
Use the laboratory’s approved control materials and clearly separated QC identification procedure. Patient results must never be entered as quality-control measurements. Verify the control material, lot, setup, and targets before recording routine QC.
How do I document a QC investigation and recovery?#
Open Control and the Investigation area (QC investigation and recovery). Select the incident under Incidents and recovery, review the affected records, and enter the corrective action taken, then choose Record action. After the action, record the required recovery control runs with the approved recovery configuration. LabProton never releases an incident automatically: a partial, warning or rejected run needs a new documented action. When the evidence is complete, an authorized user can choose Release results. Decisions about patient impact follow your laboratory’s QC procedure.
What happens to an unsaved QC entry when I leave Control?#
If a control run or investigation has unsaved entries, leaving Control asks “Are you sure you want to cancel?”. Yes discards the unsaved entries; when you return, Control shows only what was saved. No, Escape or closing the question keeps the entries and you stay on Control. While a run is being saved you cannot leave or change the configuration; wait for “QC run recorded” or the error message. Recorded runs, rule results and holds are never removed by this question.